ZC5841 Motor Tester
Classification:
Key words:Electronic testing and measuring instruments
ZC5841 is a multi-channel stepper motor life test instrument. The stepper motor is controlled by pulse signals and converts the point pulse signals into corresponding angular displacement and linear displacement micromotors. It is widely used in printers and other office equipment and various Kind of control device. The stepper motor is different from the general motor. The stepper motor cannot rotate when connected to the power supply, and it only rotates a certain angle every time a point pulse is added. In addition, when changing the pulse frequency, the speed of the stepping motor also changes. In order to monitor the running status of the stepper motor in real time, the motor parameter measurement function is designed for the drive, and the operating parameters of the motor can be obtained in real time by monitoring the working voltage and working phase current of the motor to ensure the safe and stable operation of the motor.
Stepping motors, etc.
Model |
ZC5841 |
Maximum number of connectable channels |
There are 20 channels, divided into two groups. Channels 1~10 are one group, and channels 11~20 are another group. The test parameters of each group can be set independently. The voltage of each channel can be automatically corrected. |
Operating mode |
Cyclic and continuous two methods; you can set the forward rotation time, forward rotation stop, reverse rotation time, reverse rotation stop, the number of runs, the number of cycles, and the cycle time, Various parameters such as nested loops can be used to realize customized experiments.
|
Channel management |
Each group of channels can start, stop or continue related tests at any time. |
Real-time monitoring function |
20 channels of simultaneous monitoring, the test progress bar, countdown times, voltage, current and status can be displayed on the screen in real time. |
Fault warning |
The 20 LEDs on the panel display the location of the fault channel, and the cause of the fault is displayed on the screen at the same time. |
HMI |
7-inch color LCD display, touch screen + keyboard shortcut input, Chinese interface. |
Test voltage |
2.00V~8.00V; (0.01V step) |
Drive frequency |
20PPS ~10000PPS |
Previous