PRODUCTS
Related Products
ZC2876/ZC2877/ZC2878 high frequency LCR digital bridge
Classification:
Key words:Electronic testing and measuring instruments
The high-frequency precision bridge is a multi-function component tester for testing various electronic components. It uses the most popular 7-inch 800x480 color TFT LCD display, which enables users to read test results more intuitively and comfortably. It is an impedance measuring instrument with high speed, wide test range and 6-bit test resolution, which can meet the requirements of production line quality assurance, incoming inspection and laboratory measurement.
Operating temperature, humidity |
0℃-40℃,90%RH |
|
Power requirements |
Voltage |
99V-121V 198V-242V |
frequency |
47.5Hz-63Hz |
|
Power consumption |
≤80VA |
|
Volume (W*H*D) |
398mm×129mm×370mm |
|
weight |
About 9kg |
Instrument model |
ZC2878 |
ZC2877 |
ZC2876 |
||||
Measurement function |
Test parameters |
|Z|,|Y|,C, L,X,B,R,G,D,Q,θ,DCR |
|||||
Basic measurement accuracy |
0.05% |
0.1% |
|||||
Equivalent Circuit |
Series Parallel |
||||||
Math function |
Absolute deviation |
||||||
Range method |
Automatic, hold, manual selection |
||||||
Trigger method |
Internal, manual, external, bus |
||||||
Measuring speed (≥1kHz) |
Fast: 75 times/sec (fastest) |
Fast: 200 times/sec (fastest) |
|||||
Average times |
1—255 |
||||||
Delay time |
0-60s, step by 1ms |
||||||
Calibration function |
Open circuit / short circuit / load |
||||||
Test terminal configuration |
Five ends |
||||||
List scan |
10-point list scan function |
||||||
Display method |
Direct reading, Δ, Δ%, V/I (measured voltage/current monitoring) |
||||||
monitor |
6-bit resolution, 800×480 RGB 7-inch 16: 9 TFT LCD display |
||||||
Test signal |
Test signal frequency |
20 Hz-1MHz, 10mHz resolution |
20 Hz-2MHz, 10mHz resolution |
20 Hz-5MHz, 10mHz resolution |
|||
Output impedance |
30Ω, 100Ω, 50Ω, 10/CC can be selected |
||||||
Test signal level |
Normal: 5 mV-2V |
Normal: 5 mV-5V Accuracy: 10%, 1 mV step |
|||||
DC bias source |
internal |
0V,1.5V,2V |
0V-5V continuously adjustable, 1mV step |
||||
Optional |
ZC6802A: 0-10V DC bias voltage, 0-100mA DC bias current |
||||||
ZC6802B: 0-1A DC bias current |
|||||||
Display range |
|Z|, R, X |
0.01m Ω — 99.9999 MΩ |
|||||
DCR |
1 mΩ — 99.9999 MΩ |
||||||
|Y|, G, B |
0.00001µS — 99.9999 S |
||||||
C |
0.00001 pF — 9.9999 F |
||||||
L |
0.00001 µH — 9999.99 H |
||||||
D |
0.00001 — 9.9999 |
||||||
Q |
0.00001 — 9999.9 |
||||||
θ (DEG) |
-179.999°— 179.999° |
||||||
θ (RAD) |
-3.14159 — 3.14159 |
||||||
other |
Comparator function |
Ten files: (Nine files are qualified, one file is unqualified), and there is an auxiliary file AUX |
|||||
Memory |
100 sets of internal instrument settings for storage/recall |
||||||
interface |
RS-232C, HANDLER, GPIB(optional), LAN (optional), USBTMC, USBCDC |
Related file download
2.3MB
Product Consulting