ZC9900 Series Programmable Withstand Voltage/Insulation Resistance Tester
Classification:
Key words:Electronic testing and measuring instruments
ZC9900 series AC and DC withstand voltage insulation tester is a high-performance tester using brand new technology. Its unique current protection function and high-precision output voltage enable the instrument to provide more accurate and faster tests while ensuring safety. The maximum 8 channels of withstand voltage output can better meet the all-round requirements of customers! ZC9900 series withstand voltage testers are mainly used for the safety performance testing of instruments, equipment and components!
Operating temperature, humidity |
0℃-40℃,90%RH |
|
Power requirements |
Voltage |
198V-242V |
frequency |
47.5Hz-63Hz |
|
Power consumption |
≤150VA |
|
Volume (W*H*D) |
330mm*110mm*420mm |
|
weight |
About 20kg |
Measurement accuracy and function |
||||
model |
ZC9901 |
ZC9904 |
ZC9908 |
|
Features |
ACV/DCV/IR |
ACV/DCV/IR/SCAN |
||
Output channel |
Single channel |
4 channels |
8 channels |
|
Output current |
||||
AC |
Output |
30mA |
||
measurement accuracy |
1%±5counts(5%±20 counts for real current) |
|||
Display accuracy |
1μA |
|||
frequency |
50Hz/60Hz |
|||
DC |
Output |
10mA, display accuracy: 0.1μA |
||
measurement accuracy |
1%±5counts(5%±20 counts for real current) |
|||
Display accuracy |
0.1μA |
|||
The output voltage |
||||
AC |
Output |
0.05-5kV |
||
measurement accuracy |
1% ±5V |
|||
Display accuracy |
2V |
|||
frequency |
50Hz/60Hz |
|||
power |
150VA max |
|||
DC |
Output |
0.05-6kV |
||
measurement accuracy |
1%±5V |
|||
Display accuracy |
2V |
|||
power |
Max 60VA |
|||
IR |
Output |
DC:0.05-1kV |
||
measurement accuracy |
1.5%±5V |
|||
Display accuracy |
2V |
|||
Insulation resistance |
||||
IR |
Voltage |
DC range: 0.05-1kV, voltage accuracy: 1.5%±5V |
||
Test Range |
1MΩ-50GΩ(ZC9901) |
|||
Measurement display accuracy |
0.1MΩ |
|||
measurement accuracy |
≥500V:1MΩ-1GΩ:±5%±10 counts |
|||
Protective function |
||||
Fast cut-off time |
0.4ms after NG happer |
|||
Fast discharge time |
0.2sec |
|||
Ground failure starting current |
0.5mA±0.25mA AC |
|||
(GFI) |
Close |
|||
Arc test |
||||
Setting method |
Programmable |
|||
Cut-off current range |
AC:1mA-15mA,DC:1mA-10mA |
|||
Detection time |
10μs approx |
|||
Good product and bad product judgment |
||||
Judgment display |
Good product: short sound, green light |
|||
Data retention |
The last set of test data |
|||
storage |
99 steps or 99 groups, the total does not exceed 500 steps |
Previous
Related file download
967.7KB
Product Consulting